4-20 mA Current Output Transmitter
for AC RMS Voltage or Current Input

 DIN Rail mounted, digitally programmable.
High accuracy at high update rates.

4-20 mA Current Transmitters for AC RMS Voltage or Current

 
CE Mark      RoHS Mark
Made in California

Standard Features

  • 0.2, 2, 20, 200, 300V & 600V AC RMS voltage ranges
  • 2, 20, 200 mA and 5A AC RMS current ranges
  • All input ranges selectable & factory calibrated
  • AC coupled frequencies from 10 Hz to 10 kHz
  • Crest factor of 2.4 at full scale input
  • 4-20 mA, 0-20 mA or 0-10V transmitter output, jumper selectable, isolated
  • Output resolution: 0.0015% of span (16 bits)
  • Output accuracy: ±0.15% of span
  • Switching power supply for 85-264 Vac
  • Easy setup with PC-based Instrument Setup Software
  • DIN rail mount housing only 22.5 mm wide
  • Detachable screw-clamp connectors
  • Dual solid state relays for alarm or control, isolated
  • RS232 or RS485 serial communications, isolated
  • Universal AC power, 85-264 Vac
  • Priced Reasonably (basic AC transmitter)
    Options:
  • Extended main board for custom curve linearization & rate from successive readings
  • Low voltage power, 10-48 Vdc or 12-30 Vac

Description

The Micron 4-20 mA output, AC RMS input transmitter provides six voltage input ranges and four current input ranges, all factory calibrated and jumper selectable. A special 5.000A range utilizes a built-in 0.01 ohm shunt to accept the output of 5A current transformers, with no need for a step down transformer. The current readings can easily be scaled digitally as needed.

True RMS precision circuitry is used to determine the root-mean-square of complex waveforms from 10 Hz to 10 kHz. Spikes up to 2.4 times the maximum of each range are accurately measured. This provides a crest factor (Vp / Vrms) of 240 for a signal amplitude of 1% of full scale, decreasing to 2.4 at 100% of full scale.

Three analog transmitter settings are jumper selectable: 4-20 mA, 0-20 mA or 0-10V. The output tracks the reading up to 99,999 counts that would be transmitted digitally. For AC RMS signals, this reading has an accuracy of 0.1% of full scale from 1% to 100%, 10 Hz to 10 kHz, and can be calibrated in software. Output isolation from signal and power grounds eliminates potential ground loop problems. The supply can drive 20 mA into a 500 ohm (or lower) load for 10V compliance, or 10V into a 5K ohm (or higher) load for 2 mA compliance.

Standard features of Micron transmitters include:

  • Analog transmitter output, 16-bit, user scalable and isolated. User selectable 4-20 mA, 0-20 mA or 0-10V levels.
  • Serial communications, isolated. User selectable RS232 or RS485, half or full duplex, Modbus or Micron ASCII protocol.
  • Dual solid state relays for control or alarm, isolated. Rated 120 mA at 130 Vac or 170 Vdc.
  • Universal AC power supply for 85-264 Vac.

Easy Transmitter programming is via Micron's Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Micron (P/N CBL04).


Specifications
Micron 4-20 mA Transmitter for AC RMS Voltage or Current Input

Range

Voltage Ranges
(1% to 100% of FS)

  200.00 mV  
2.0000 V
20.000 V
200.00 V
600.0 V

10 µV
100 µV
1 mV
10 mV
100 mV

1 Mohm

Current Ranges
(1% to 100% of FS)

2.0000 mA
20.000 mA
200.00 mA
5.000 A

0.1 µA
1 µA
10 µA
1 mA

100 ohms
10 ohms
1 ohm
0.01 ohm

A-to-D Resolution
Conversion Accuracy
Input Settling Time
Max Applied Voltage
Current Protection
16 bit A/D converter
0.1% of full scale from 1% to 100%, 10 Hz to 10 kHz
1 sec to 0.1% of step
600 Vac for 20, 200 & 600 V ranges, 50 Vac other ranges
25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5A
Analog Output (standard)
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Isolation
4-20 mA, 0-20 mA, 0-10 Vdc (jumper selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load or higher)
16 bits (65,536 steps)
0.02% of output span plus conversion accuracy
250V rms working, 2.3 kV rms per 1 minute test
Dual Relay Output (standard)
Relay Type
Load rating
Two solid state relays, SPST, normally open, Form A
130 mA at 140 Vac or 180 Vdc
Serial Communications (standard)
Signal Types
Data Rates
Output Isolation
Serial Protocols
Modbus Modes
Modbus Compliance
Digital Addressing
RS232 or RS485 (half or full duplex)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Micron ASCII
RTU or ASCII
Modbus over Serial Line Specification V1.0 (2002)
247 Modbus addresses.
Up to 32 devices on an RS485 line w/o a repeater.
Power Input
Standard power
Low power option
Power frequency
Power isolation
Power consumption
85-264 Vac or 90-300 Vdc (DC operation not UL approved)
10-48 Vdc or 12-30 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2 Watts
Mechanical
Case Dimensions
Case Mounting
Electrical Connections
120 x 101 x 22.5 mm
35 mm rail per DIN EN 50022
Detachable screw-clamp plugs
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Protection
Cooling Required
0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted
Mount transmitters so that ventilation holes are at top and bottom.
Leave 6 mm (1/4") between transmitters, or blow air by means of a fan.

 

Pinout
Micron 4-20 mA Transmitter for AC RMS Voltage or Current Input