Standard Features
|
DescriptionThe Micron Modbus & serial output, AC RMS input transmitter provides six voltage input ranges and four current input ranges, all factory calibrated and jumper selectable. A special 5.000A range utilizes a built-in 0.01 ohm shunt to accept the output of 5A current transformers, with no need for a stepdown transformer. The current readings can easily be scaled digitally as needed. True RMS precision circuitry is used to determine the root-mean-square of complex waveforms from 10 Hz to 10 kHz. Spikes up to 2.4 times the maximum of each range are accurately measured. This provides a crest factor (Vp / Vrms) of 240 for a signal amplitude of 1% of full scale, decreasing to 2.4 at 100% of full scale. LTM Series serial output transmitters send data via an isolated serial port, which is user configurable for RS232 or RS485 and full or half duplex operation. Three protocols are user selectable: Modbus RTU, Modbus ASCII, or Micron ASCII. Modbus operation is fully compliant with Modbus Over Serial Line Specification V1.0 (2002). The Micron ASCII protocol allows up to 31 Micron devices to be addressed on the same RS485 data line. It is simpler than the Modbus protocol and is recommended when all devices are Microns. It also allows use of Micron Datalogging Software. Standard features of Micron transmitters include:
Easy Transmitter programming is via Micron's Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Micron (P/N CBL04). |
AC RMS Input |
Range |
Resolution |
Input Ohms |
Voltage Ranges (1% to 100% of full scale) |
200.00 mV 2.0000 V 20.000 V 200.00 V 600.0 V |
10 µV 100 µV 1 mV 10 mV 100 mV |
1 Mohm |
Current Ranges (1% to 100% of full scale) |
2.0000 mA 20.000 mA 200.00 mA 5.000 A |
0.1 µA 1 µA 10 µA 1 mA |
100 ohms 10 ohms 1 ohm 0.01 ohm |
A-to-D Resolution Conversion Accuracy Input Settling Time Max Applied Voltage Over-current Protection |
16 bit A/D converter 0.1% of scale from 1% to 100%, 10 Hz to 10 kHz 1 sec to 0.1% of step 600 Vac for 20, 200 & 600 V ranges, 50 Vac other ranges 25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5A |
||
Serial Data Output (standard) |
|||
Signal Types Data Rates Output Isolation Serial Protocols Modbus Modes Modbus Compliance Digital Addressing |
RS232 or RS485 (half or full duplex) 300, 600, 1200, 2400, 4800, 9600, 19200 baud 250V rms working, 2.3 kV rms per 1 min test Modbus RTU, Modbus ASCII, Micron ASCII RTU or ASCII Modbus over Serial Line Specification V1.0 (2002) 247 Modbus addresses. Up to 32 devices on RS485 line w/o a repeater. |
||
Dual Relay Output (standard) |
|||
Relay Type Load rating |
Two solid state relays, SPST, normally open, Form A 120 mA at 130 Vac or 170 Vdc, 28 ohms series resistance |
||
Analog Output (standard) |
|||
Output Levels Compliance, 4-20 mA Compliance, 0-10V Output Resolution Output Accuracy Output Isolation |
4-20 mA, 0-20 mA, 0-10 Vdc (jumper selectable) 10V ( 0-500 ohm load ) 2 mA ( 5 kOhm load or higher) 16 bits (65,536 steps) 0.02% of output span plus conversion accuracy 250V rms working, 2.3 kV rms per 1 minute test |
||
Power Input |
|||
Standard power Low power option Power frequency Power isolation Power consumption |
85-264 Vac or 90-300 Vdc (DC operation not UL approved) 10-48 Vdc or 12-30 Vac DC or 47-63 Hz 250V rms working, 2.3 kV rms per 1 min test 2 Watts |
||
Mechanical |
|||
Case Dimensions Case Mounting Electrical Connections |
120 x 101 x 22.5 mm 35 mm rail per DIN EN 50022 Detachable screw-clamp plugs |
||
Environmental |
|||
Operating Temperature Storage Temperature Relative Humidity Protection Cooling Required |
0°C to 55°C -40°C to 85°C 95% at 40°C, non-condensing NEMA-4X (IP-65) when panel mounted Mount transmitters so that ventilation holes are at top and bottom. Leave 6 mm (1/4") between transmitters, or blow air by means of a fan. |
||